AC Leaking Water Inside the House? What to Do First
Short answer: AC leaking water inside is usually a clogged condensate drain line, a frozen evaporator coil or a cracked drain pan [1][2]. Turn the system off, replace a dirty filter, let any ice thaw, and check the drain line. Clearing a clogged line often costs under $150 [1], or $100 to $450 in DFW [4].
AC leaking water inside the house is most often a clogged condensate drain line, a frozen evaporator coil or a cracked or rusted drain pan [1][2]. Turn the system off at the thermostat first to stop more water, then work through the checks below. If the cause is a part or refrigerant problem, see our AC repair cost in Texas guide for prices, or get a free quote from local Texas pros.
Step 0: Stop the water and stay safe
- Turn the AC off at the thermostat, and at the disconnect or breaker if you know how. This stops the system making more condensate [1].
- Dry the area and move belongings. Water from units in attics, closets and basements can go unnoticed long enough to badly damage ceilings, floors and walls [3].
- Don't chip ice off a frozen coil. Let it thaw with cooling off; it may take several hours [1].
- Hissing, frost or weak cooling can mean a refrigerant leak, which needs an EPA-certified technician [1].
What should you check, in order?
- The air filter. A dirty filter restricts airflow, the coil freezes, and the melt overflows the pan. Replace it if it looks dirty; Bryant suggests about every one to three months [1].
- Ice on the indoor coil or copper lines. If you see ice, leave cooling off until it melts, then see our AC freezing up guide [1][2].
- The condensate drain line. This PVC pipe carries water from the indoor unit to the outside and can clog with algae, mold, dust or debris [1][2]. Check where it exits; a wet/dry vacuum can clear a minor clog if you can safely identify the line [1].
- The drain pan. Look under the indoor unit for cracks, rust or standing water. Pans corrode over time, more often in older systems [1][2].
- The float (safety) switch. If the AC shut itself off and the pan holds water, a water-level switch probably tripped. That switch is meant to shut the system down before the pan overflows [3]. Clear the cause; never bypass it.
- A condensate pump, if your system has one. If it fails, clogs or loses power, water backs up and overflows [1].
- Call a pro if you can't find the source, water keeps coming back, the coil keeps freezing, or you suspect refrigerant [1][2].
What does the fix usually cost?
| Fix | Typical cost |
|---|---|
| Clear a clogged drain line | Often under $150 [1]; condensate drain or pump work $100–$450 in DFW [4]; $350 flat at one North Texas company [5] |
| Refrigerant leak repair plus recharge | $400–$2,500 in DFW [4]; $350–$1,000 at one flat-rate company [5] |
- Drain pan replacement: $1,200 at one flat-rate company [5].
- Float switch: $400 at the same company [5].
- Frozen evaporator coil repair: $300–$900 on one Arlington list [6].
These are posted company and guide prices, not a survey of invoices. For city prices see AC repair cost in Arlington, Houston or San Antonio.
Why Texas homes see this more
- Attic units. Most Dallas-Fort Worth homes have the air handler and coil in the attic [4], so an overflow shows up as a ceiling stain, not a puddle you see right away [3].
- Long, humid cooling seasons. Systems pull more water out of humid air, and a North Texas guide notes drain clogs are common in humid stretches [4]. High humidity can also make an AC produce more condensate than the drain handles [1].
- Safety pans and switches. DOE Building America guidance notes the International Residential Code requires a secondary drain pan under the coil when an overflow would damage the building, and a water-level (float) switch that shuts the system off before a pan overflows [3]. Ask your tech to confirm yours works.
How do you keep it from happening again?
- Change filters on schedule and get a spring tune-up that includes the drain line [1][2].
- Keep the area around the indoor unit clean [2].
- Check the drain pan now and then for standing water or rust [3].
- A water leak sensor next to the indoor unit can alert you to an overflow early [1].
Water still coming through the ceiling? See water leaking from the ceiling: what to do, or get a free quote from local Texas pros.
FAQ
Why is my AC leaking water inside the house?
The most common causes are a clogged condensate drain line, a frozen evaporator coil, or a damaged or rusted drain pan; a dirty filter often causes the frozen coil [1][2].
Can I still run my AC if it's leaking water?
Both Bryant and Trane recommend turning it off and getting it repaired, because running it can cause water damage or harm the system [1][2].
How much does it cost to fix an AC that is leaking water?
Clearing a clogged drain line is often under $150 [1]; DFW guides list $100 to $450 for drain or pump work [4]. A drain pan replacement can run $1,200 at one company [5].
Why did my AC shut off with water in the pan?
A water-level (float) switch is designed to shut the system off before the pan overflows [3]. Clear the clog rather than bypassing the switch.
Sources
- Bryant, Why Is My Air Conditioner Leaking Water & What Should I Do?
- Trane, AC Leaking Water? Find Out Why and What to Do
- U.S. DOE Building America Solution Center (PNNL), HVAC Has Corrosion-Resistant Condensate Drain Pan
- The North Texas Home Guide, AC Repair Costs in North Texas (2026; updated Oct 22, 2026)
- Frosty's HVAC, AC Repair in Arlington, TX (flat-rate price list, 2026)
- LocalFixCost, AC Repair Cost Arlington TX (2026; updated August 2026)
Request received! Someone will reach out to you soon.
Get a free quote from a local pro
Tell us what you need. With your permission, one named local Texas pro can reach out with a quote. Free, no obligation.